Description
Human TNF-α Kit (HICA)Product Specification Stability & Storage Store at 2~8C protected from light for 12 months; after reconstitution, the standard can be aliquoted and stored at 20C, avoiding repeated freeze thaw cycles. Background Test Principle: This kit employs a homogeneous immuno chemiluminescence assay (HICA) for the detection of cytokine concentrations. The operation is simple and requires no washing steps. The detection system consists of two types of
Product Specification
| Stability & Storage | Store at 2~8°C protected from light for 12 months; after reconstitution, the standard can be aliquoted and stored at -20°C, avoiding repeated freeze-thaw cycles. |
Background
Test Principle:
This kit employs a homogeneous immuno chemiluminescence assay (HICA) for the detection of cytokine concentrations. The operation is simple and requires no washing steps.
The detection system consists of two types of microspheres: acceptor microspheres conjugated with antibody 1 targeting the protein of interest, and donor microspheres conjugated with streptavidin, along with biotin-labeled antibody 2. During the reaction, the target protein binds with the antibodies and microspheres to form an immune complex, bringing the two types of microspheres into close proximity. When the distance between the donor and acceptor microspheres is less than 200 nm, singlet oxygen generated upon light excitation can transfer to the acceptor microspheres, triggering chemiluminescence. Conversely, if the target protein is absent, the microspheres remain too far apart, and no signal is produced.
By measuring the intensity of the chemiluminescent signal, the target protein can be quantitatively analyzed. This method features simplicity of operation, rapid reaction, and high sensitivity.
Components
Here is the translated content in English, maintaining the original HTML format:```html
Name |
Specification |
Component Specification |
Detection ReagentR1 |
500T |
2mL/bottle×1 |
2000T |
8ml/bottle×1 |
|
10000T |
40ml/bottle×1极 |
|
Detection ReagentR2 |
500T |
2mL/bottle×1 |
2000T |
8ml/bottle×1 |
|
10000T |
40ml/bottle×1 |
|
Detection ReagentR3 |
500T极 |
5mL/bottle×1 |
2000T |
20ml/bottle×1 |
|
10000T |
100ml/bottle×1 |
|
Standard |
500T |
0.05μg lyophilized×1 |
2000T |
0.05μg lyophilized×2 |
|
10000T |
0.05μg lyophilized×5 |
|
Standard Buffer |
500T |
6mL/bottle×1 |
2000T |
12ml/bottle×1 |
|
10000T |
30ml/bottle×1 |
Note: The recommended plates are microplates (384 or 96 wells, white, shallow well)
```Guidelines
Reagent R3 should be protected from light during use, and sample addition and incubation are recommended to be performed under green light (<100 LUX).
Each test requires recalibration, with at least duplicate wells for each concentration point of the standard. A four-parameter (weighting 1/Y²) fitting method should be used for calculation.
Temperature and time should be carefully controlled during incubation. Microplates should be covered with film, and a microplate reader with ALPHA function is recommended.
The dilution matrix for calibrators should match the sample matrix, and reconstituted calibrators should be used within 2 hours.
Components from different reagent kit lots must not be mixed.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy