SKU: 12258561642

HKM-068307 24-Hour 3-Channel ECG Holter Monitor with PC Software Analysis System

Sale price$171.00 Regular price$190.00
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 10 - Jul 15

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

HKM-068307 24-Hour 3-Channel ECG Holter Monitor with PC Software Analysis SystemIntroducing the HKM 068307 24 Hour 3 Channel ECG Holter Monitor, a reliable and comprehensive solution for continuous ECG waveform recording and analysis. This advanced device is designed to meet the needs of medical institutions and community healthcare settings, providing essential insights into patient heart health. Equipped with a 3 lead system, the HKM 068307 records ECG data in real time for a full 24 hours. With its sophisticated PC software

Introducing the HKM-068307 24-Hour 3-Channel ECG Holter Monitor, a reliable and comprehensive solution for continuous ECG waveform recording and analysis. This advanced device is designed to meet the needs of medical institutions and community healthcare settings, providing essential insights into patient heart health.

Equipped with a 3-lead system, the HKM-068307 records ECG data in real-time for a full 24 hours. With its sophisticated PC software analysis system, healthcare professionals can conduct thorough arrhythmia assessments using MCSSTM and TMCATM technologies, significantly streamlining their workflow.

Key functions include:

- Over 10 predefined templates to identify various pathologic waveforms such as atrial fibrillation, ventricular premature beats, and more, alongside many user-defined modules for enhanced customization.
- The ability to select any lead as the primary analysis channel, allowing for flexible and tailored analysis.
- Advanced atrial fibrillation analysis with options for both AUTO and manual reviews, increasing the precision of diagnoses.
- Comprehensive pacemaker analysis capabilities to evaluate all types, including AAI, VVI, and DDD.
- Fast review analysis for single or full-lead ECG data, ensuring prompt interpretation of results.

Additional unique features include a one-key print option for convenient report generation and a robust case management function. The HKM-068307 also provides insightful risk assessments, such as predicting sleep breath pause syndrome and death risk in myocardial infarction patients through its specialized analysis functions.

With a sampling accuracy of 24-bit and a frequency of 250Hz, the HKM-068307 is engineered for high performance. Its user-friendly USB2.0 interface and battery operation make it a practical choice for any medical professional seeking accuracy and efficiency in ECG monitoring.

This ECG Holter Monitor stands as a testament to modern cardiac care technology, combining functionality and ease of use to assist healthcare providers effectively.

Introduction

Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
5)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
6)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
7)With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
8)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
9)With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
10)One-key print, convenient and fast to print the reports.
11)Perfect case management function.
12)The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
13)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
14)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death


Performance
Lead: 3-lead
Record time: ≥24-hour
Power supply: two “AA” alkaline batteries
Interface: USB2.0
Sampling accuracy: 24bit
Sampling frequency: 250Hz
Dynamic range: 10mV
Input impedance: ≥10MΩ
CMR: ≥60dB
Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
System noise: ≤50µVp-p
Multichannel crosstalk: ≤0.2mV
Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
Minimum measure signal: 50 µV
With the function in the presence of pacemaker pulses
Timing accuracy: the overall error during 24h shall not exceed 30s.




Accessories
Lead cable (1 set)
ECG electrode (1 bag)
USB cable(1)
Bag(1)
User manual(1)


Physical characteristic
Dimension: 111mm(L) × 61mm(W) × 25mm(H)
Weight: about 105g(without batteries)

Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 12258561642

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 136 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
A
Amazon Reviewer
Port Orchard, US
★★★★★ 4
Great ingredients - very strong scent
Size: 16 Fl Oz (Pack of 1)
I have really dry skin and frequent eczema so ordered this lotion to try out. I use a standard colloidal oatmeal lotion typically and it's hard to find a good lotion that doesn't have petrolatum. This one uses olive and jojoba oils instead. I ran it through a product safety app and it scored a 93/100 which is REALLY good for an eczema lotion - the only potential problematic ingredient is peppermint leaf which can be an allergen for some folks. It comes with a pump for easy use and I didn't find the lotion too greasy or oily - it seemed to absorb well. My only problem with the lotion is how strong the tea tree oil scent is - I use eczema lotion at bedtime and the smell was so strong, it was keeping me awake. If you're sensitive to tea tree oil, that could be an issue. But it's great for daytime use and has a nice, fresh scent. It's preventing the dryness and cracking on my hands that typically happens with "normal" lotions so the oat kernel flour is doing its job. As long as you don't have an aversion to a strong tea tree oil scent, this is a perfect eczema lotion. I've only ever found a handful of them that don't use petrolatum and I appreciate that this one uses plant oils instead. It works to keep the hands from drying or cracking. The price tag is on point with the other eczema lotion I use with it currently being $21 for 16 oz. Definitely recommend this if you are looking for an ingredient-safe eczema lotion.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 26, 2025
L
Verified Purchase
Luling wang
Grantham, US
★★★★★ 5
Works for itchy dry skin
Size: 16 Fl Oz (Pack of 1)
Works good
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 9, 2026
D
Verified Purchase
Desert Rain
Carnegie, US
★★★★★ 5
Best hand cream for extreme rough hands
Size: 16 Fl Oz (Pack of 1)
My husband struggles with really rough hands and it's the best thing we've found. It does have a bit of a medicinal smell, but well worth it for the relief! Highly recommend.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 3, 2026
S
Verified Purchase
Shelia
Charlottesville, US
★★★★★ 3
Smells like a disinfectant
Size: 16 Fl Oz (Pack of 1)
I’ve been struggling with eczema terribly this winter, scratching to the point of bruising. Nothing seems to help so I figured I’d give this a try. I will say that it does provide instant relief, but it is short lived and not worth the scent. It smells terrible and reminds me of old fashion Pine Sol. I think there are better products out there. I wouldn’t buy this again.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on February 25, 2026
K
Verified Purchase
Kindle Customer
Natrona Heights, US
★★★★★ 5
Help relieved the burn
Size: 16 Fl Oz (Pack of 1)
Helped to clear up skin
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 26, 2026

recommand products