
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 7 - Jul 12
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human TFAM ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be sonicated or repeatedly freeze-thawed. Finally, centrifuge the homogenate at 5000×g for 5-10 minutes and remove the supernatant for analysis. Cell culture supernatant: Centrifuge at 1000×g for 20 minutes. Remove the supernatant for analysis or store at -20°C or -80°C, but avoid repeated freeze-thaw cycles. Pre-Assay Preparation: 1. Remove the reagent kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let stand for 15 minutes to completely dissolve, then gently mix (concentration 20 ng/mL). Then dilute to the following concentrations: 20 ng/mL, 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each tube. Pipette 500uL of the 20ng/mL standard working solution into the first EP tube and mix thoroughly to make a 10ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube is used as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Transcription Factor A, Mitochondrial (TFAM) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the Transcription Factor A, Mitochondrial (TFAM) content in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Transcription Factor A, Mitochondrial ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Mitochondrial transcription factor A (TFAM) is a protein encoded by the TFAM gene. This gene encodes a mitochondrial transcription factor that is a key activator of mitochondrial transcription and a participant in mitochondrial genome replication. It binds to mitochondrial promoter DNA to facilitate mitochondrial genome transcription. It is a double-box, high-mobility group DNA binding and bending protein. This bending function is important for mitochondrial transcription initiation in mammals, but not in its yeast homolog, Abf2. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.312-20 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenate, cell culture supernatant |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.4 ★★★★★
Based on 1508 reviews
Sort
Product Reviews
★★★★★ 5
waterproof
This bikini trimmer is a compact, handheld device, roughly the size of a lipstick tube, that operates on a rechargeable battery and comes with a USB charging cable and a protective cap. I have been using this trimmer for a little over a week now as part of my personal grooming routine. I initially picked this item because I was looking for a small, waterproof tool that could be used quickly and efficiently. I appreciate that the body is made out of a smooth, waterproof plastic, which I think makes it easy to clean and feels hygienic for both wet and dry use.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 11, 2025
★★★★★ 5
Handy Compact Trimmer
I really like how this trimmer has two functions in one, it makes things super convenient. It’s small and easy to hold, so I can use it on different areas without feeling awkward. I tried it on both legs and underarms, and it gave a smooth finish without irritation. The design makes it easy to switch between trimming and shaving, which is a nice touch. I also appreciate that it’s waterproof, so I can just rinse it clean after using it. Overall, it feels like a simple and practical tool to keep around for quick grooming.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 1, 2025
★★★★★ 5
Bikini Trimmer for Women
This bikini trimmer l bought for my wife comes with every attachments for her need,such as body hair,the bikini line and underarms and more. its design is sleek and minimalist. the trimmer is compact and powerful,easy to handle,and very effective,which makes shaving quick and smooth. the trimmer also be gentle on her skin,no pulling or causing any irritation. she said she feels comfortable to hold in the hand. she likes how quietly it works and how long the battery lasts compared with the old one. and wide variety of attachments are easy to change and clean. overall different interchangeable heads make it incredibly versatile,that will satisfy all of her hair removal needs! this trimmer set is a must have for her.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 6, 2025
★★★★★ 5
efficiently remove body hair
It is excellent bikini trimmer to trim overgrown hair. Works great and super easy to use. It's easy to handle, charges quickly, and trims without irritation. I like the 2 in 1 dual side design. The round head hair remover works very efficient and after removal of arm hair, I don't feel any pain. And the residue hair could be released from the device easily. Perfect for travel or quick touch-ups at home. Love the cute design and color. It is affordable bikini trimmer that gets the job done without irritation or nicks.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 5, 2025
★★★★★ 5
Functional
I used to get cuts when using regular razors but ever since I switched to this electric razor, I no longer have to worry about getting hurt. The blade is extremely sharp yet gentle and provides a smooth shave on my face, legs, underarms and other areas without any pain. The waterproof feature makes cleaning easy. I can simply rinse it under the tap. The rechargeable design is also very convenient. It's small and portable easy to take on business trips and travels! The shaver glides smoothly on underarms and the detailer head gives perfect shaping for bikini lines. Fully waterproof for shower use and the self cleaning blades rinse effortlessly.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 4, 2025
recommand products
Juniper Moon Farm Zooey Spray - Pacific Sunset (Color #307)
11.99
MaggieFrame Magnetic Hoop 8.5"x9" | 215x230mm for Inbro
85.95
MaggieFrame Magnetic Hoop 6.9" | 175x175mm for YONTHIN
95.00
MaggieFrame Magnetic Hoop 12"x11.5" | 305x295mm for MAYA
1617.00
MaggieFrame Magnetic Hoop 7.7"x12.5" | 195x315mm for YONTHIN
95.00